Jump to Main Content
PubAg
Main content area
Search
« Previous |
1 - 20 of 34
|
Next »
Search Results
- Author:
- Kobayashi, Norihiro; Banzono, Erika; Shimoda, Yuko; Oyama, Hiroyuki; Kunihiro, Toshiomi; Morita, Izumi; Ohta, Mitsuhiro
- Source:
- Analytical methods 2011 v.3 no.9 pp. 1995-2002
- ISSN:
- 1759-9679
- Subject:
- amino acid sequences; analytical methods; biotin; chloroform; cotinine; cross reaction; dose response; enzyme-linked immunosorbent assay; humans; hybridomas; immunoglobulin G; metabolites; mice; monoclonal antibodies; myeloma; nicotine; nitrogen oxides; smoke; splenocytes; streptavidin; tobacco; urine
- Abstract:
- ... Immunoassays for human urinary cotinine [(S)-(−)-cotinine], a major nicotine metabolite, are useful to monitor the degree of tobacco smoke exposure. However, practical monoclonal antibodies for measuring urinary cotinine are not widely available. Here we generated a monoclonal antibody against a newly prepared cotinine–albumin conjugate and developed an enzyme-linked immunosorbent assay (ELISA). S ...
- DOI:
- 10.1039/c1ay05083d
-
http://dx.doi.org/10.1039/c1ay05083d
- Author:
- Vela-Soria, F.; Jiménez-Díaz, I.; Rodríguez-Gómez, R.; Zafra-Gómez, A.; Ballesteros, O.; Fernández, M. F.; Olea, N.; Navalón, A.
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2073-2081
- ISSN:
- 1759-9679
- Subject:
- adverse effects; animal tissues; atmospheric pressure; benzophenones; bisphenol A; calibration; centrifugation; chemical residues; chemical species; detection limit; endocrine-disrupting chemicals; ethyl acetate; humans; ionization; liquid chromatography; methylparaben; placenta; tandem mass spectrometry; wildlife; women; Spain
- Abstract:
- ... The group of compounds commonly called endocrine-disrupting chemicals covers a wide range of synthetic and natural substances able to alter the normal hormone function of wildlife and humans, consequently causing adverse health effects. Bisphenol A (BPA) and its chlorinated derivatives, benzophenones (BPs) and parabens (PBs), belong to this group of compounds. In this work, we propose a multiclass ...
- DOI:
- 10.1039/c1ay05162h
-
http://dx.doi.org/10.1039/c1ay05162h
- Author:
- Islam, Aminul; Ahmad, Akil; Laskar, Mohammad Asaduddin
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2041-2048
- ISSN:
- 1759-9679
- Subject:
- analytical methods; cadmium; chromium; cobalt; copper; detection limit; fish; green leafy vegetables; hydrogen; lead; mango pulp; metal ions; nickel; pH; sorption; zinc
- Abstract:
- ... Salicylanilide has been incorporated into Amberlite XAD-16 through an azo spacer. Characterization of the synthesized resin was done on the basis of elemental analyses, infra-red spectral and thermal studies. The water regain value and hydrogen ion capacity were found to be 12.90 and 6.08 mmol g⁻¹ respectively. The optimum pH values for the maximum sorption of analyte were 9.0 for Cu(ii), Co(ii), ...
- DOI:
- 10.1039/c1ay05217a
-
http://dx.doi.org/10.1039/c1ay05217a
- Author:
- Kumar JhaPresent address: Department of Nanoscience & Engineering, Myongji University, Yongin, Gyeonggi, South Korea 449-728, Sandeep; D'Souza, Stanislaus F.
- Source:
- Analytical methods 2011 v.3 no.9 pp. 1981-1987
- ISSN:
- 1759-9679
- Subject:
- analytical methods; catalase; catalytic activity; cell culture; color; computer software; computers; dissolved oxygen; electrodes; electronic circuits; enzyme activity; foods; hydrogen peroxide; instrumentation; microbial detection; milk; monitoring; oxygen; spectrophotometers; turbidity; viscosity
- Abstract:
- ... A novel approach for estimation of catalase activity in biological samples was developed using real-time signal averaging with LabVIEW based virtual instrumentation. The assay was performed by on-line monitoring of the increase in dissolved oxygen concentration due to the catalytic reaction of the enzyme with its substrate H₂O₂ using a Clark type dissolved oxygen electrode. The electrode was inter ...
- DOI:
- 10.1039/c0ay00760a
-
http://dx.doi.org/10.1039/c0ay00760a
- Author:
- Janssen, Kris P. F.; Knez, Karel; Pollet, Jeroen; Roberts, Scott J.; Schrooten, Jan; Lammertyn, Jeroen
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2156-2159
- ISSN:
- 1759-9679
- Subject:
- capillary electrophoresis; gene amplification; oligonucleotides; proteins
- Abstract:
- ... Affinity probe capillary electrophoresis (APCE) holds promise to be a powerful tool in diagnostic applications that rely on the selective and sensitive detection of proteins. Aptamers can serve to unlock the full potential of the technology since their use opens up possibilities to unite the immuno-sensing and separating strength of capillary electrophoresis with the signal enhancement power of nu ...
- DOI:
- 10.1039/c1ay05124e
-
http://dx.doi.org/10.1039/c1ay05124e
- Author:
- Kong, Yong; Chen, Xiaohui; Yao, Chao; Ma, Mengjie; Chen, Zhidong
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2121-2126
- ISSN:
- 1759-9679
- Subject:
- analytical methods; catechol; detection limit; electrochemistry; glassy carbon electrode; hydroquinone; isomers; oxidation; quinones
- Abstract:
- ... A simple and reliable voltammetric sensor for simultaneous determination of hydroquinone (HQ) and catechol (CC) was developed on an electrochemically activated glassy carbon electrode (GCE). The cyclic voltammograms in a mixed solution of HQ and CC have shown that the oxidation peaks become well resolved and were separated by 108 mV, although the bare GCE gave a single broad oxidation peak. Moreov ...
- DOI:
- 10.1039/c1ay05331k
-
http://dx.doi.org/10.1039/c1ay05331k
- Author:
- Gregson, Colin R.; Hastings, Jeremy J.; Sims, Howard E.; Steele, Helen M.; Taylor, Robin J.
- Source:
- Analytical methods 2011 v.3 no.9 pp. 1957-1968
- ISSN:
- 1759-9679
- Subject:
- analytical methods; effluents; encapsulation; isotopes; nuclear fuels; oxidation; plutonium; ponds; radionuclides; silos; sludge; solubility; total suspended solids; United Kingdom
- Abstract:
- ... Within the UK there are a number of nuclear legacy fuel storage ponds and silos that contain substantial volumes of corroding spent Magnox fuel pieces. The fuel and wastes within these ponds, including highly radioactive sludges, must be retrieved and processed during decommissioning. Sludges and other intermediate level wastes will then be encapsulated in a wasteform suitable for storage and disp ...
- DOI:
- 10.1039/c1ay05313b
-
http://dx.doi.org/10.1039/c1ay05313b
- Author:
- Tsukagoshi, Masamichi; Kitahara, Yuki; Takahashi, Seiji; Tsugoshi, Takahisa; Fujii, Toshihiro
- Source:
- Analytical methods 2011 v.3 no.9 pp. 1943-1947
- ISSN:
- 1759-9679
- Subject:
- activation energy; liquids; mass spectrometry; temperature; thermal degradation
- Abstract:
- ... We investigated the thermal decomposition of Japanese lacquer liquid and films, which are non-volatile complex natural materials, by means of evolved gas analysis-ion attachment mass spectrometry. The thermal decomposition products are identified by analysis of the mass spectra of degraded samples. The mass chromatogram (pyrogram) of the products generated at various temperatures with kinetic trea ...
- DOI:
- 10.1039/c1ay05215b
-
http://dx.doi.org/10.1039/c1ay05215b
- Author:
- Mourya, Sandeep-Kumar; Bose, Devasish; Durgbanshi, Abhilasha; Esteve-Romero, Josep; Carda-Broch, Samuel
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2032-2040
- ISSN:
- 1759-9679
- Subject:
- chemical species; environmental monitoring; guidelines; health hazards; high performance liquid chromatography; industrial wastes; industry; nitroanilines; pH; pentanols; risk; wastewater
- Abstract:
- ... Aromatic amines are extensively used in industry but they are classified as a potential environment and health hazard. A new high performance liquid chromatography method has been developed and optimized, for the determination of eight banned aromatic amines: benzidine, o-anisidine, o-phenylenediamine, o-nitroaniline, 2-methoxy-5-methylaniline (p-cresidine), o-toluidine, p-toluidine and p-chloroan ...
- DOI:
- 10.1039/c0ay00602e
-
http://dx.doi.org/10.1039/c0ay00602e
- Author:
- dos Santos, Karen C.; da Silva, Maria Fátima G. F.; Fernandes, João B.; Vieira, Paulo C.; Polikarpov, Igor; Zucolotto, Valtencir; Forim, Moacir R.
- Source:
- Analytical methods 2011 v.3 no.9 pp. 1936-1942
- ISSN:
- 1759-9679
- Subject:
- acetonitrile; lactones; nanoparticles; pH; polyhydroxybutyrate; polymethylmethacrylate; reversed-phase high performance liquid chromatography; temperature; thyroid hormones; triethylamine; wavelengths
- Abstract:
- ... The objective of this work was to develop and validate a rapid Reversed-Phase High-Performance Liquid Chromatography method for the quantification of 3,5,3′-triiodothyroacetic acid (TRIAC) in nanoparticles delivery system prepared in different polymeric matrices. Special attention was given to developing a reliable reproductive technique for the pretreatment of the samples. Chromatographic runs we ...
- DOI:
- 10.1039/c1ay05169e
-
http://dx.doi.org/10.1039/c1ay05169e
- Author:
- Segundo, Ricardo Alves; Mesquita, Raquel Beatriz Ribeiro; Ferreira, Maria Teresa Soares Oliveira Barbosa; Teixeira, Catarina Fernanda Carvalho Pinheiro; Bordalo, Adriano Agostinho; Rangel, António Osmaro Santos Silva
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2049-2055
- ISSN:
- 1759-9679
- Subject:
- absorbance; ammonia; ammonium; brackish water; coastal water; detection limit; estuaries; green chemistry; salinity; spectroscopy; standard deviation
- Abstract:
- ... This work describes the development of a sequential injection system for the ammonium determination in transitional and coastal waters with a wide salinity range. Estuarine waters are rather complex matrices as their characteristics change considerably along the salinity gradient, as well as the ammonium levels. The developed system effectively solves these issues by converting ammonium into ammon ...
- DOI:
- 10.1039/c1ay05129f
-
http://dx.doi.org/10.1039/c1ay05129f
- Author:
- Chandrasekaran, Krishnan; Karunasagar, Dheram; Arunachalam, Jayaraman
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2140-2147
- ISSN:
- 1759-9679
- Subject:
- ammonium; atomic absorption spectrometry; calibration; cetyltrimethylammonium bromide; chelating agents; chloroform; detection limit; fluorometry; graphs; groundwater; hydrophobicity; liquid-phase microextraction; mass spectrometry; nitric acid; pH; seawater; solvents; surfactants; uranium; uranyl ions
- Abstract:
- ... A dispersive liquid–liquid microextraction (DLLME) method was developed for the determination of uranium(vi) in groundwater/seawater by inductively coupled plasma–optical emission spectrometry (ICP–OES) and flow injection–inductively coupled plasma mass spectrometry (FI–ICPMS). This is the first report on the extraction of uranium(vi) by a DLLME method. In this method, uranium(vi) was complexed wi ...
- DOI:
- 10.1039/c1ay05329a
-
http://dx.doi.org/10.1039/c1ay05329a
- Author:
- Rao, Yanying; Chen, Qingfeng; Kong, Fanjuan; Dong, Jian; Qian, Weiping
- Source:
- Analytical methods 2011 v.3 no.9 pp. 1969-1974
- ISSN:
- 1759-9679
- Subject:
- 4-hydroxybenzoic acid; L-dopa; Raman spectroscopy; cinnamic acid; enzyme activity; enzymes; gold; hydroxylation; nanocomposites; nanogold; nanoparticles; sensors (equipment); silica; tyrosine
- Abstract:
- ... Here we report a novel method for detecting 3,4-dihydroxyphenylalanine (l-DOPA) and tyrosinase (TR) activity based on surface-enhance Raman scattering (SERS) by employing a large-scale versatile three-dimensionally (3D) ordered nanocomposite (SiO₂/GNPs) array as a nanosensor. l-DOPA could reduce AuCl₄⁻ to Au⁰ and enlarge the gold nanoparticles (GNPs) that attach on the surface of the SiO₂/GNPs arr ...
- DOI:
- 10.1039/c1ay05208j
-
http://dx.doi.org/10.1039/c1ay05208j
- Author:
- Staymates, Jessica L.; Grandner, Jessica; Gillen, Greg
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2056-2060
- ISSN:
- 1759-9679
- Subject:
- explosives; fiberglass; narcotics; screening; silicone; spectroscopy
- Abstract:
- ... Improving particle collection efficiency for swipe-based sampling systems can provide a better chance of detection when screening for trace explosives or narcotics particles. A technique was developed to improve the particle collection efficiency of commercially-available collection swabs used for field sampling of trace contraband materials. A silicone adhesive was added to Teflon-coated fibergla ...
- DOI:
- 10.1039/c1ay05299c
-
http://dx.doi.org/10.1039/c1ay05299c
- Author:
- Sanbonsuge, Aya; Takase, Tsugiko; Shiho, Den-ichiro; Takagai, Yoshitaka
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2160-2164
- ISSN:
- 1759-9679
- Subject:
- ambient temperature; carbon tetrachloride; catalysts; derivatization; detection limit; eprinomectin; gas chromatography-mass spectrometry; horse meat; ionization; ivermectin; liquid chromatography; monitoring; moxidectin; organosilicon compounds; solvents; veterinary drugs
- Abstract:
- ... A gas chromatography-mass spectrometric (GC-MS) method utilizing electron impact ionization has been developed for the quantitation of the antiparasitic agent, ivermectin (IVM). The approach is based upon the pre-column derivatization of IVM by reaction with N,O-bis(trimethylsilyl)tri-fluoroacetamide (BSTFA) in the presence of 1-methylimidazole as catalyst and carbon tetrachloride as solvent to fo ...
- DOI:
- 10.1039/c1ay05236e
-
http://dx.doi.org/10.1039/c1ay05236e
- Author:
- Wang, Guangfeng; Zhang, Ge; Huang, Hao; Wang, Lun
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2082-2087
- ISSN:
- 1759-9679
- Subject:
- analytical methods; antigens; blood serum; detection limit; electrochemistry; graphene; humans; hydrogen peroxide; immunoassays; immunosensors; nanogold; nanoparticles; normal values
- Abstract:
- ... A new electrochemical immunosensor for the determination of carcinoembryonic antigen (CEA) was developed with a Graphene (Gr)-Prussian blue (PB)/gold nanoparticles (GNP) immobilization platform. HRP-anti-CEA was immobilized on the platform and with the immunoreactions, the formed immunocomplex inhibited partly the bioactive center of the immobilized HRP, and decreased the HRP toward the reduction ...
- DOI:
- 10.1039/c1ay05294b
-
http://dx.doi.org/10.1039/c1ay05294b
- Author:
- Sha, Jun; Wang, Yaolei; Wang, Jianchun; Liu, Wenming; Tu, Qin; Liu, Ajing; Wang, Lei; Wang, Jinyi
- Source:
- Analytical methods 2011 v.3 no.9 pp. 1988-1994
- ISSN:
- 1759-9679
- Subject:
- Escherichia coli; analytical methods; case studies; droplet size; droplets; genomics; heat stress; microfluidic technology; oils; plasmids; quartz
- Abstract:
- ... This work describes an improved method for monodispersed water-in-oil droplet formation and collection using a composite microfluidic device composed of a poly(dimethylsiloxane) (PDMS) microfluidic device and a commercially available quartz capillary. The application of the method to chemical heat-shock (CaCl₂-dependent) transformation of Escherichia coli (E. coli) is also presented. With this app ...
- DOI:
- 10.1039/c1ay05189j
-
http://dx.doi.org/10.1039/c1ay05189j
- Author:
- Cao, Haiyan; Shi, Wenbing; Xie, Jianxin; Huang, Yuming
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2102-2107
- ISSN:
- 1759-9679
- Subject:
- atomic absorption spectrometry; catalytic activity; copper; fluorescence; fluorescence emission spectroscopy; hydrogen peroxide; lakes; oxidation; p-cresol; rivers; standard deviation; swimming pools
- Abstract:
- ... It was found that Cu²⁺ has a great catalytic effect on p-cresol oxidation by hydrogen peroxide under alkaline conditions, leading to an intense fluorescence signal due to the fast formation of 2,2′-dihydroxy-5,5′-dimethylbiphenyl, an oxidation product of p-cresol. Investigation of the fluorescence spectra of the p-cresol–hydrogen peroxide system demonstrated the catalytic behavior of Cu²⁺. On this ...
- DOI:
- 10.1039/c1ay05298e
-
http://dx.doi.org/10.1039/c1ay05298e
- Author:
- Hoa, Nguyen Duc; El-Safty, Sherif A.
- Source:
- Analytical methods 2011 v.3 no.9 pp. 1948-1956
- ISSN:
- 1759-9679
- Subject:
- acetone; adsorption; analytical methods; benzene; catalytic activity; cupric oxide; ethanol; ferric oxide; nanocomposites; nanocrystals; nickel oxide; porous media; silica; tin dioxide; transmission electron microscopy; volatile organic compounds; zinc oxide
- Abstract:
- ... We introduce the use of highly ordered mesoporous silica/metal oxide (HOM/MO) nanocomposite monoliths for volatile organic compound (VOC) gas sensor applications. Monoliths with various loadings of semiconducting metal oxides (SnO₂, ZnO, NiO, CuO, and Fe₂O₃) were prepared through instant direct-templating method. The dependence of the doping elements and doping levels on the mesoporous structure o ...
- DOI:
- 10.1039/c1ay05333g
-
http://dx.doi.org/10.1039/c1ay05333g
- Author:
- Prakash, S.; Shahi, Vinod K.
- Source:
- Analytical methods 2011 v.3 no.9 pp. 2134-2139
- ISSN:
- 1759-9679
- Subject:
- analytical methods; cadmium; detection limit; glassy carbon electrode; lead; metal ions; nanosilver; oxygen; silver; surfactants; wastewater; India
- Abstract:
- ... Silver nanonuts (AgNns) with controlled size were electrodeposited on a glassy carbon electrode (GCE) surface using a double pulse potentiostatic technique for simultaneous detection of Pb²⁺ and Cd²⁺ in water samples without removal of oxygen, surfactant and other metal ions. The AgNns decorated GCE electrode showed improved sensitivity and reproducibility in comparison with previously reported el ...
- DOI:
- 10.1039/c1ay05265a
-
http://dx.doi.org/10.1039/c1ay05265a