Jump to Main Content
PubAg
Main content area
Search
Search Results
- Author:
- Zhou, Zhixue; Zhu, Chengzhou; Ren, Jiangtao; Dong, Shaojun
- Source:
- Analytica chimica acta 2012 v.740 pp. 88-92
- ISSN:
- 0003-2670
- Subject:
- cost effectiveness; deoxyribonuclease I; enzymatic reactions; fluorescein; fluorescence; graphene; hydrolysis; quantitative analysis; single-stranded DNA
- Abstract:
- ... Using the remarkable difference in the affinity of graphene oxide (GO) with double strand DNA (dsDNA) and short DNA fragments, we report for the first time a GO-based nonrestriction nuclease responsive system. Our system was composed of GO and a fluorescent dye fluorescein amidite (FAM)-labeled dsDNA substrate (F-dsDNA). At first, the fluorescence of this F-dsDNA substrate was quenched upon additi ...
- DOI:
- 10.1016/j.aca.2012.06.032
-
http://dx.doi.org/10.1016/j.aca.2012.06.032
- Author:
- Bagheri, Habib; Es’haghi, Ali; Es-haghi, Ali; Mesbahi, Noushin
- Source:
- Analytica chimica acta 2012 v.740 pp. 36-42
- ISSN:
- 0003-2670
- Subject:
- bitertanol; chlorpyrifos-methyl; cucumbers; detection limit; diazinon; gas chromatography-mass spectrometry; malathion; markets; mixing; monitoring; pesticide residues; phosalone; polytetrafluoroethylene; silicon; solid phase microextraction; solvents; stainless steel
- Abstract:
- ... A high-throughput solid-phase microextraction (SPME) on 96-well plate together with gas chromatography–mass spectrometry (GC–MS) was developed for the determination of some selected pesticides in cucumber samples. Pieces with the length of 1.0cm of silicon tubing were precisely prepared and then coated on the end part of stainless steel wires. The prepared fibers were positioned in a home-made pol ...
- DOI:
- 10.1016/j.aca.2012.06.001
-
http://dx.doi.org/10.1016/j.aca.2012.06.001
- Author:
- Zhang, Daohong; Li, Peiwu; Zhang, Qi; Li, Ran; Zhang, Wen; Ding, Xiaoxia; Li, Chang Ming
- Source:
- Analytica chimica acta 2012 v.740 pp. 74-79
- ISSN:
- 0003-2670
- Subject:
- aflatoxin B1; antibodies; binding sites; cost effectiveness; detection limit; immunoaffinity chromatography; toxicity
- Abstract:
- ... It is critical to develop a cost-effective quantitative/semiquantitative assay for rapid diagnosis and on-site detection of toxic or harmful substances. Here, a naked-eye based semiquantitative immunochromatographic strip (NSI-strip) was developed, on which three test lines (TLs, TL-I, TL-II and TL-III) were dispensed on a nitrocellulose membrane to form the test zone. Similar as the traditional s ...
- DOI:
- 10.1016/j.aca.2012.06.015
-
http://dx.doi.org/10.1016/j.aca.2012.06.015
- Author:
- Capriotti, Anna Laura; Caruso, Giuseppe; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Laganà, Aldo
- Source:
- Analytica chimica acta 2012 v.740 pp. 58-65
- ISSN:
- 0003-2670
- Subject:
- biomarkers; blood serum; digestion; hydrocolloids; molecular weight; nanoparticles; peptides; proteins; proteolysis; proteome; proteomics; spectrometers; ultrafiltration
- Abstract:
- ... Serum low-molecular weight (LMW) proteins potentially contain useful biological information and their identification can be used to discover novel potential biomarkers. Given the high complexity of serum samples, in the last years several different prefractionation and enrichment strategies have been developed. In this study three different methods, i.e. hydrogel nanoparticles, Proteominer® peptid ...
- DOI:
- 10.1016/j.aca.2012.06.033
-
http://dx.doi.org/10.1016/j.aca.2012.06.033
- Author:
- Cochran, R.E.; Dongari, N.; Jeong, H.; Beránek, J.; Haddadi, S.; Shipp, J.; Kubátová, A.
- Source:
- Analytica chimica acta 2012 v.740 pp. 93-103
- ISSN:
- 0003-2670
- Subject:
- air; derivatization; gas chromatography-mass spectrometry; ionization; methane; monitoring; oxidation; particulates; polycyclic aromatic hydrocarbons; smoke; solid phase extraction; temperature
- Abstract:
- ... A sensitive method has been developed for the trace analysis of PAHs and their oxidation products (i.e., nitro-, oxy-, and hydroxy-PAHs) in air particulate matter (PM). Following PM extraction, PAHs, nitro-, oxy-, and hydroxy-PAHs were fractionated using solid phase extraction (SPE) based on their polarities. Gas chromatography–mass spectrometry (GC–MS) conditions were optimized, addressing inject ...
- DOI:
- 10.1016/j.aca.2012.05.050
-
http://dx.doi.org/10.1016/j.aca.2012.05.050
- Author:
- Joshi, Manishkumar D.; Steyer, Daniel J.; Anderson, Jared L.
- Source:
- Analytica chimica acta 2012 v.740 pp. 66-73
- ISSN:
- 0003-2670
- Subject:
- aqueous solutions; boron; hydrochloric acid; ionic liquids; liquid-phase microextraction; lithium; nuclear magnetic resonance spectroscopy; seawater; sodium chloride
- Abstract:
- ... Glucaminium-based ionic liquids are a new class of solvents capable of extracting boron-species from water with high efficiency. The complexation behavior of these ILs with borate was thoroughly studied using ¹¹B NMR. Two different complexes, namely, monochelate complex and bischelate complex, were observed. ¹¹B NMR was used extensively to determine the formation constants for monochelate and bisc ...
- DOI:
- 10.1016/j.aca.2012.06.035
-
http://dx.doi.org/10.1016/j.aca.2012.06.035
- Author:
- Culzoni, María J.; Aucelio, Ricardo Q.; Escandar, Graciela M.
- Source:
- Analytica chimica acta 2012 v.740 pp. 27-35
- ISSN:
- 0003-2670
- Subject:
- Alzheimer disease; acetonitrile; ammonium acetate; analytical chemistry; blood serum; cholinesterase; data collection; detection limit; fluorescence; high performance liquid chromatography; least squares; metabolites; patients; prediction; wavelengths
- Abstract:
- ... Based on green analytical chemistry principles, an efficient approach was applied for the simultaneous determination of galantamine, a widely used cholinesterase inhibitor for the treatment of Alzheimer's disease, and its major metabolites in serum samples. After a simple serum deproteinization step, second-order data were rapidly obtained (less than 6min) with a chromatographic system operating i ...
- DOI:
- 10.1016/j.aca.2012.06.034
-
http://dx.doi.org/10.1016/j.aca.2012.06.034
- Author:
- Krishnan, Shaji; Vogels, Jack T.W.E.; Coulier, Leon; Bas, Richard C.; Hendriks, Margriet W.B.; Hankemeier, Thomas; Thissen, Uwe
- Source:
- Analytica chimica acta 2012 v.740 pp. 12-19
- ISSN:
- 0003-2670
- Subject:
- chromatography; mass spectrometry; metabolites; molecular weight; solvents; spectrometers; washing
- Abstract:
- ... Setting appropriate bin sizes to aggregate hyphenated high-resolution mass spectrometry data, belonging to similar mass over charge (m/z) channels, is vital to metabolite quantification and further identification. In a high-resolution mass spectrometer when mass accuracy (ppm) varies as a function of molecular mass, which usually is the case while reading m/z from low to high values, it becomes a ...
- DOI:
- 10.1016/j.aca.2012.06.014
-
http://dx.doi.org/10.1016/j.aca.2012.06.014
- Author:
- Villaverde-de-Sáa, Eugenia; Racamonde, Inés; Quintana, José Benito; Rodil, Rosario; Cela, Rafael
- Source:
- Analytica chimica acta 2012 v.740 pp. 50-57
- ISSN:
- 0003-2670
- Subject:
- carboxylic acids; desorption; detection limit; freshwater; ionic strength; liquid chromatography; pH; perfluorocarbons; polar compounds; polymers; prices; sewage; solvents; surface water; tandem mass spectrometry
- Abstract:
- ... A method for the determination of seven perfluorinated carboxylic acids and perfluorooctane sulphonate (PFOS) in aqueous samples using low-cost polymeric sorptive extraction as sample preparation technique, followed by liquid chromatography–tandem mass spectrometry (LC–MS/MS) determination has been developed and validated. Simplicity of the analytical procedure, low volume of solvent and sample re ...
- DOI:
- 10.1016/j.aca.2012.06.027
-
http://dx.doi.org/10.1016/j.aca.2012.06.027
- Author:
- Ríos, Ángel; Zougagh, Mohammed; Avila, Mónica
- Source:
- Analytica chimica acta 2012 v.740 pp. 1-11
- ISSN:
- 0003-2670
- Subject:
- Biological Sciences; chemistry; medicine
- Abstract:
- ... Micro total analysis (μTAS), also called “lab-on-a-chip (LOC)” technology, promises solutions for high throughput and highly specific analysis for chemistry, biology and medicine, while consuming only tiny amounts of samples, reactants and space. This article reports selected contributions of LOC, which represent clear practical approaches for routine work, or presenting potentiality to be transfe ...
- DOI:
- 10.1016/j.aca.2012.06.024
-
http://dx.doi.org/10.1016/j.aca.2012.06.024
- Author:
- Bagheri, Habib; Alipour, Noshin; Ayazi, Zahra
- Source:
- Analytica chimica acta 2012 v.740 pp. 43-49
- ISSN:
- 0003-2670
- Subject:
- cetyltrimethylammonium bromide; desorption; detection limit; gas chromatography-mass spectrometry; micelles; microextraction; monitoring; multiresidue analysis; nanowires; pH; pesticides; polymers; river water; scanning electron microscopy; solvents; triazines
- Abstract:
- ... A simple, rapid and sensitive method based on microextraction in packed syringe (MEPS), in combination with gas chromatography–mass spectrometry (GC–MS) was developed. Polyaniline (PANI) nanowires network was synthesized and used as sorbent of MEPS for the multiresidue determination of selected analytes from triazine, organochlrorine and organophosphorous pesticides in aqueous samples. The PANI na ...
- DOI:
- 10.1016/j.aca.2012.06.026
-
http://dx.doi.org/10.1016/j.aca.2012.06.026
- Author:
- Zhang, Wenzhu; Zhang, Run; Zhang, Jingmei; Ye, Zhiqiang; Jin, Dayong; Yuan, Jingli
- Source:
- Analytica chimica acta 2012 v.740 pp. 80-87
- ISSN:
- 0003-2670
- Subject:
- aqueous solutions; biotechnology; cysteine; detection limit; diagnostic techniques; dose response; glutathione; image analysis; photoluminescence; ruthenium; thiols
- Abstract:
- ... Photoluminescence (PL) and electrochemiluminescence (ECL) detection techniques are highly sensitive and widely used methods for clinical diagnostics and analytical biotechnology. In this work, a unique ruthenium(II) complex, [Ru(bpy)₂(DNBSO-bpy)](PF₆)₂ (bpy: 2,2′-bipyridine; DNBSO-bpy: 2,4-dinitrobenzenesulfonate of 4-(4-hydroxyphenyl)-2,2′-bipyridine), has been designed and synthesized as a highl ...
- DOI:
- 10.1016/j.aca.2012.06.028
-
http://dx.doi.org/10.1016/j.aca.2012.06.028
- Author:
- Li, Hong-Dong; Xu, Qing-Song; Liang, Yi-Zeng
- Source:
- Analytica chimica acta 2012 v.740 pp. 20-26
- ISSN:
- 0003-2670
- Subject:
- Markov chain; algorithms; colon; data collection; disease diagnosis; frogs; gene expression; genes; microarray technology; models
- Abstract:
- ... The identification of disease-relevant genes represents a challenge in microarray-based disease diagnosis where the sample size is often limited. Among established methods, reversible jump Markov Chain Monte Carlo (RJMCMC) methods have proven to be quite promising for variable selection. However, the design and application of an RJMCMC algorithm requires, for example, special criteria for prior di ...
- DOI:
- 10.1016/j.aca.2012.06.031
-
http://dx.doi.org/10.1016/j.aca.2012.06.031