Theoretical effect of unequal water levels on the infiltration rate determined with buffered cylinder infiltrometers

Author:
Bouwer, H.
Source:
Journal of hydrology 1963 v.1 no.1 pp. 29
ISSN:
0022-1694
Subject:
soil water, water flow, infiltrometers, hydraulic conductivity, buffers
Abstract:
Differences in water level between cylinder and buffer of a buffered infiltrometer installation cause the infiltration rate as calculated from outflow from the inner cylinder to be in error. The author determines the error in relation to the water level difference between cylinder and buffer, the diameter and depth of installation of the cylinder, and the final hydraulic gradient.