Destruction of Spores on Building Decontamination Residue in a Commercial Autoclave

Author:
Lemieux, P., Sieber, R., Osborne, A., Woodard, A.
Source:
Applied and environmental microbiology 2006 v.72 no.12 pp. 7687-7693
ISSN:
0099-2240
Subject:
temperature profiles, bags, decontamination, Geobacillus stearothermophilus, indicator species, steam, autoclaves, standard operating procedures, thermocouples, tiles, furniture, home furnishings, water content, bacterial spores, Bacillus anthracis, anthrax, United States
Abstract:
The U.S. Environmental Protection Agency conducted an experiment to evaluate the effectiveness of a commercial autoclave for treating simulated building decontamination residue (BDR). The BDR was intended to simulate porous materials removed from a building deliberately contaminated with biological agents such as Bacillus anthracis (anthrax) in a terrorist attack. The purpose of the tests was to assess whether the standard operating procedure for a commercial autoclave provided sufficiently robust conditions to adequately destroy bacterial spores bound to the BDR. In this study we investigated the effects of several variables related to autoclaving BDR, including time, temperature, pressure, item type, moisture content, packing density, packing orientation, autoclave bag integrity, and autoclave process sequence. The test team created simulated BDR from wallboard, ceiling tiles, carpet, and upholstered furniture, and embedded in the BDR were Geobacillus stearothermophilus biological indicator (BI) strips containing 10⁶ spores and thermocouples to obtain time and temperature profile data associated with each BI strip. The results indicated that a single standard autoclave cycle did not effectively decontaminate the BDR. Autoclave cycles consisting of 120 min at 31.5 lb/in² and 275°F and 75 min at 45 lb/in² and 292°F effectively decontaminated the BDR material. Two sequential standard autoclave cycles consisting of 40 min at 31.5 lb/in² and 275°F proved to be particularly effective, probably because the second cycle's evacuation step pulled the condensed water out of the pores of the materials, allowing better steam penetration. The results also indicated that the packing density and material type of the BDR in the autoclave could have a significant impact on the effectiveness of the decontamination process.
Agid:
587457