U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

PubAg

Main content area

Multiresidue determination of pesticides from aquatic media using polyaniline nanowires network as highly efficient sorbent for microextraction in packed syringe

Author:
Habib Bagheri, Noshin Alipour, Zahra Ayazi
Source:
Analytica chimica acta 2012 v.740 no. pp. 43-49
ISSN:
0003-2670
Subject:
cetyltrimethylammonium bromide, desorption, detection limit, gas chromatography-mass spectrometry, micelles, microextraction, monitoring, multiresidue analysis, nanowires, pH, pesticides, polymers, river water, scanning electron microscopy, solvents, triazines
Abstract:
A simple, rapid and sensitive method based on microextraction in packed syringe (MEPS), in combination with gas chromatography–mass spectrometry (GC–MS) was developed. Polyaniline (PANI) nanowires network was synthesized and used as sorbent of MEPS for the multiresidue determination of selected analytes from triazine, organochlrorine and organophosphorous pesticides in aqueous samples. The PANI nanowires network was prepared using soft template technique and its characterization was studied by scanning electron microscopy (SEM). The presence of micelles in this methodology showed to be an important parameter in shaping the growing polymer. Hexadecyltrimethylammonium bromide (HTAB) was used as structure directing agent in PANI preparation procedure and this was led to the formation of nanowires with diameters ranging from 35nm to 45nm. The synthesized PANI nanowires network showed higher extraction capability in comparison with the bulk PANI. Important parameters influencing the extraction and desorption processes including desorption solvent, elution volume, draw–eject cycles of sample, draw–eject mode, pH effect and amount of sorbent were optimized. Limits of detection were in the range of 0.07–0.3ngmL⁻¹ using time scheduled selected ion monitoring (SIM) mode. The linearity of method was in the range from 0.5–200ngmL⁻¹ to 0.2–1000ngmL⁻¹. The method precision (RSD %) with three replicates were in the range of 5.3–18.4% at the concentration level of 5ngmL⁻¹. The developed method was successfully applied to the Zayandeh-rood river water samples and the matrix factor obtained for the spiked real water samples were in the range of 0.79–0.94.
Agid:
857875