PubAg

Main content area

Carbon nanotube–chitosan modified disposable pencil graphite electrode for Vitamin B₁₂ analysis B Biointerfaces

Author:
Kuralay, Filiz, Vural, Tayfun, Bayram, Cem, Denkbas, Emir Baki, Abaci, Serdar
Source:
Colloids and surfaces 2011 v.87 no.1 pp. 18-22
ISSN:
0927-7765
Subject:
chitosan, colloids, dielectric spectroscopy, drugs, electrochemistry, electrodes, graphene, scanning electron microscopy
Abstract:
A single walled carbon nanotube–chitosan (SWCNT–chitosan) modified disposable pencil graphite electrode (PGE) was used in this study for the electrochemical detection of Vitamin B₁₂. Electrochemical behaviors of SWCNT–chitosan PGE and chitosan modified PGE were compared by using cyclic voltammetry (CV), square-wave voltammetry (SWV) and electrochemical impedance spectroscopy (EIS) techniques. SWCNT–chitosan modified electrode was also used for the quantification of Vitamin B₁₂ in pharmaceutical products. The results show that this electrode system is suitable for sensitive Vitamin B₁₂ analysis giving good recovery results. The surface morphologies of the SWCNT–chitosan PGE, chitosan modified PGE and unmodified PGE were characterized by using scanning electron microscopy (SEM).
Agid:
956243